SurgeX
517 North
Industrial Drive, Zebulon, NC
27597
Customer Service:
800-645-9721
Technical Support:
800-645-9721
Fax:
919-269-0454
www
.surgex.com
Hardware Installation Guide
Axess Ready Branch Circuit
Surge Eliminator/Power Conditioner
USER
MANUAL
SOFTWARE VERSION: 1.01.41
FIRMWARE VERSION: 1.01.06
Page view 0
1 2 3 4 5 6 ... 28 29

Summary of Contents

Page 1 - Axess Ready Branch Circuit

SurgeX • 517 North Industrial Drive, Zebulon, NC 27597 Customer Service: 800-645-9721 • Technical Support: 800-645-9721 • Fax: 919-269-0454 • www.surg

Page 2 - Table of Contents

SX-20NE-RT-AR User Manual Page 9 V. Initial Set-Up (continued) Manage Open Browser: Opens the web browser interface for the selected AR. Up

Page 3

SX-20NE-RT-AR User Manual Page 10 V. Initial Set-Up (continued) Setting the IP Address ARs are configured with a factory default IP address

Page 4 - I. Introduction

SX-20NE-RT-AR User Manual Page 11 VI. Web Server The Axess Ready web interface provides the easiest means of operating the outlet and chang

Page 5

SX-20NE-RT-AR User Manual Page 12 VI. Web Server (continued) Setup Pages Setup pages are only available while logged in with Administrator

Page 6 - II. Installation

SX-20NE-RT-AR User Manual Page 13 VI. Web Server (continued) Network IP Mode: Select Static to manually set the IP address using the fields

Page 7 - III. LED Indicators

SX-20NE-RT-AR User Manual Page 14 VI. Web Server (continued) AutoPing The AutoPing feature allows the AR to automatically detect failed e

Page 8

SX-20NE-RT-AR User Manual Page 15 VI. Web Server (continued) • Action: Select the action to be triggered. None AutoPing not used Power On

Page 9

SX-20NE-RT-AR User Manual Page 16 VI. Web Server (continued) Schedule The AR can schedule up to 8 recurring power events. For each event, y

Page 10 - V. Initial Set-Up

SX-20NE-RT-AR User Manual Page 17 VI. Web Server (continued) Passwords Two passwords are used by the AR. The User password allows control of

Page 11

SX-20NE-RT-AR User Manual Page 18 VII. Command Line Interface (CLI) Protocol The Command Line Interface provides complete setup of all functio

Page 12 - VI. Web Server

SX-20NE-RT-AR User Manual Page 1 Table of Contents I. INTRODUCTION 3 II. INSTALLATION 5 PHYSICAL

Page 13

SX-20NE-RT-AR User Manual Page 19 VII. Command Line Interface (CLI) Protocol (continued) Network Commands Command Description Admin Fact Def g

Page 14

SX-20NE-RT-AR User Manual Page 20 VII. Command Line Interface (CLI) Protocol (continued) AutoPing Commands Command Description Admin Fact Def

Page 15

SX-20NE-RT-AR User Manual Page 21 VII. Command Line Interface (CLI) Protocol (continued) Event Commands Command Description Admin Fact Def ge

Page 16

SX-20NE-RT-AR User Manual Page 22 VIII. DxP Protocol Overview The DxP Protocol is a packet-based protocol designed to be extensible. This pro

Page 17

SX-20NE-RT-AR User Manual Page 23 VIII. DxP Protocol (continued) DxP Packet The packet is broken up into 2 parts: the Header and the Paylo

Page 18

SX-20NE-RT-AR User Manual Page 24 VIII. DxP Protocol (continued) Commands There are currently 7 command classes. All classes are defined in

Page 19 - Page 18

SX-20NE-RT-AR User Manual Page 25 VIII. DxP Protocol (continued) eCmnd_io typedef enum{ eIO_null, eIO_changeRelay, eIO_changeRelays,

Page 20 - (continued)

SX-20NE-RT-AR User Manual Page 26 VIII. DxP Protocol (continued) Payloads TChangeRelay typedef struct{ unsigned char relay; unsigned ch

Page 21

SX-20NE-RT-AR User Manual Page 27 X. Firmware Upgrades XI. Reset Button The AR can be upgraded via the network if the upgrade feature h

Page 22

SX-20NE-RT-AR User Manual Page 28 XI. Specifications Physical Model Width Depth Height Weight SX-20NE-RT-AR 12.0” 4.0” 12.0” 14 lb. Temper

Page 23 - VIII. DxP Protocol

SX-20NE-RT-AR User Manual Page 2 Table of Contents (continued) VII. COMMAND LINE INTERFACE (CLI) PROTOCOL 18 PROMPTS

Page 24 - VIII. DxP Protocol

SX-20NE-RT-AR User Manual Page 3 I. Introduction The SurgeX® SX-20NE-RT-AR is a network attached, IP addressed, web controlled AC surge elimi

Page 25

SX-20NE-RT-AR User Manual Page 4 I. Introduction (continued) Located on the front panel are: • Remote LED • Self-Test L

Page 26

SX-20NE-RT-AR User Manual Page 5 II. Installation Physical The SX-20NE-RT-AR is housed in a magnetic shielding NEMA enclosure designed to

Page 27

SX-20NE-RT-AR User Manual Page 6 III. LED Indicators IV. Remote Control Connections AXESS ON The Axess Ready system is On. The AR sy

Page 28 - XI. Reset Button

SX-20NE-RT-AR User Manual Page 7 IV. Remote Control Connections (continued) b) Contact Closure/Latching Switch: The unit will power up when

Page 29 - XI. Specifications

SX-20NE-RT-AR User Manual Page 8 V. Initial Set-Up Device Management Utility (DMU) The SurgeX Device Management Utility (DMU) provides t